1800 915 825

info@bowmanheatexchangers.com.au

Air Cooled Heat Exchangers - Charge Air Cooler - Air Heat Exchanger

Charge Air Cooler

Charge Air Coolers

Bowman charge air heat exchangers are ideal for cooling marine engines as well as various land based engines such as gensets, co-generation equipment and fire pumps. They are also suitable for facilitating engine test and development programs. Additional charge air coolers designed for specific engines are also available; please see the website or contact the sales department for further information.


Performance Details/Leistungsdetails/Performance Thermiques

Part No. Charge Air Flow (kg/min) Pressure Drop (kpa) Water Flow (lit/min) Pressure Drop (kpa) Heat Rejection (kW) Engine Power
EC140-4218-4 2.5 2.2 30 10 6.5 50
FC100-4074-2 4.3 3.1 90 20 11.2 90
FG100-4075-2 9.8 5.4 140 29 25.4 190
GL140-4076-2 15.4 7.4 215 24 40 300
GK190-4877-3 20.3 9.6 200 11 52 350
JK190-4078-3 30.1 9.4 200 12 65 500
PK190-4079-3 40.3 8.6 200 4 100 800

The above figures are based on Air temperature from 180°C to 50°C at 1.75 Bar G, using water temperature at 20°C.


Installation Drawings

EC140-4218-4 / FC100-4074-2 / FG100-4075-2 / GL140-4076-2 / GK190-4877-3

PART NO. A B C D E F G H I J K L M N
mm mm mm mm mm mm 4 holes mm mm mm mm mm mm BSP
EC140-4218-4
444 312 66 52 94 288 M8x12 53 47 85 20 55 52 3/4"
FC100-4074-2 358 190 84 52 120 190 M8x12 67 59 100 25 63 76 1"
FG100-4075-2 472 272 100 76 132 190 M8x12 69 70 110 32 70 76 1 1/4"
GL140-4076-2 502 272 115 76 166 108 M10x15 85 85 130 38 90 120 1 1/2"
GK190-4877-3 674 370 152 89 206 236 M12x18 103 103 180 50 110 120 2"

JK190-4078-3

PK190-4079-3

Maximum Air Inlet temperature 250°C. For higher charge air temperatures please contact Bowman.

Bowman charge air coolers must not be operated without adequate water flow.